Atlas Copco Refrigerated Air Dryer FX 1-16

Atlas Copco Refrigerated Air Dryer FX 1-16

orCall 18121319076

Description

 

 FX 1-16 Refrigerant air dryers

FX refrigerant dryers - the smart choice

 

The benefits add up :

 

Solid performance

 

Steady pressure dew point

 

No freezing of condensed moisture

 

No chance of moisture entering the compressed air system.

 

Simple reliability

 

Quality components, generously sized

 

Simple and proven design

 

Effective control system (hot gas bypass).

 

Easy Installation

 

Plug and play concept

 

Single electrical connection

 

All units pre-commissioned

 

Self regulating.

 

Minimal maintenance

 

Long service intervals

 

Few component replacements

 

Ergonomic design for fast access to key components.

 

Significant cost savings

 

Increased reliability and lifetime of tools and equipment

 

Reduced pipe work leaks, meaning reduced energy bill

 

Fewer repairs to tools, machines and pipe work

 

Less inconvenient breakdowns and stoppages

 

Minimal chance of product spoilage through moisture carryover.

 

Air purification

 

No installation is complete without filtration

 

Technical data

 

Technical specification : 50 Hz version

 

Model

Outlet pressure dew point

Maximum working pressure

Electrical supply

Compressed air connections

 

+ 5 °C / 41 °F

+ 3 °C / 37 °F

 

-

 
 

Inlet capacity

Pressure drop

Inlet capacity

Pressure drop

 

-

 
 

m³/min

bar

m³/min

bar

-

 

FX 1

0.42

0.20

0.36

0.15

16

230/1/50 Hz

3/4" M

FX 2

0.72

0.33

0.60

0.25

16

230/1/50 Hz

3/4" M

FX 3

0.96

0.33

0.84

0.25

16

230/1/50 Hz

3/4" M

FX 4

1.38

0.33

1.20

0.25

16

230/1/50 Hz

3/4" M

FX 5

2.10

0.40

1.80

0.30

16

230/1/50 Hz

3/4" M

FX 6

2.70

0.42

2.34

0.32

13

230/1/50 Hz

1" F

FX 7

3.48

0.50

3.0

0.38

13

230/1/50 Hz

1" F

FX 8

4.15

0.24

3.60

0.18

13

230/1/50 Hz

1 1/2" F

FX 9

4.75

0.33

4.09

0.25

13

230/1/50 Hz

1 1/2" F

FX 10

6.01

0.24

5.23

0.18

13

230/1/50 Hz

1 1/2" F

FX 11

7.51

0.26

6.49

0.20

13

230/1/50 Hz

1 1/2" F

FX 12

8.89

0.36

7.69

0.27

13

230/1/50 Hz

1 1/2" F

FX 13

11.53

0.33

10.03

0.25

13

400/3/50 Hz

2" F

FX 14

13.82

0.40

12.02

0.30

13

400/3/50 Hz

2" F

FX 15

17.30

0.40

15.02

0.30

13

400/3/50 Hz

2" F

FX 16

20.73

0.40

18.02

0.30

13

400/3/50 Hz

2" F

 

Reference conditions

 

• Ambient temperature : 25 °C • Inlet temperature : 35 °C • Working pressure : 7 bar(g)

 

Notes :

 

Refrigerant types: • R134a for FX 1-5 • R404a for FX 6-16

 

Limitations :

 

• Max. ambient temp.: 43 °C • Min. ambient temp.: 5 °C • Max. inlet temp.: 55 °C

 

Filter selection

 

 

+ 5 °C / 41 °F

+ 3 °C / 37 °F

 

Inlet capacity

Pre filter

After filter

Inlet capacity

Pre filter

After filter

 

l/s

-

l/s

-

FX 1

7

DD9

PD9

6

DD9

PD9

FX 2

12

DD17

PD17

10

DD17

PD17

FX 3

16

DD17

PD17

14

DD17

PD17

FX 4

23

DD32

PD32

20

DD32

PD32

FX 5

35

DD44

PD44

30

DD32

PD32

FX 6

45

DD44

PD44

39

DD44

PD44

FX 7

58

DD60

PD60

50

DD60

PD60

FX 8

69

DD120

PD120

60

DD60

PD60

FX 9

79

DD120

PD120

68

DD120

PD120

FX 10

100

DD120

PD120

87

DD120

PD120

FX 11

125

DD120

PD120

108

DD120

PD120

FX 12

148

DD150

PD150

128

DD150

PD150

FX 13

192

DD280

PD280

167

DD175

PD175

FX 14

230

DD280

PD280

200

DD280

PD280

FX 15

288

DD280

PD280

250

DD280

PD280

FX 16

345

DD280

PD280

300

DD280

PD280

 

 Flow diagram

Refrigerant circuit

1. Refrigerant separator : ensures that only refrigerant gas can enter the compressor, as liquid would cause damage.

 

2. Refrigerant compressor : brings the gaseous refrigerant to a high pressure and a high temperature.

 

3. Max. pressure switch(only FX13-15)

 

4. Fan control pressure switch(only FX13-15)

 

5. Condenser fan

 

6. Condenser : cools the refrigerant slightly so that it changes from gas to liquid; refrigerant is more effective in the liquid state.

 

7. Capillary filter : protects the expansion device from harmful particles.

 

8. Capillary tube : reduces the refrigerant’s pressure, thereby lowering its temperature and increasing its cooling capacity; the refrigerant is now almost all liquid, with some residual gas.

 

9. Hot gass bypass : regulates the amount of refrigerant passing through the air-to-refrigerant heat exchanger, ensuring a stable pressure dewpoint, and eliminating the chance of the condensate freezing.

 

Air circuit

 

10. Air inlet : hot saturated air enters the dryer and is cooled by the outgoing air via the air-to-air heat exchanger. Reducing the temperature of the inlet air reduces the load on the refrigerant circuit.

 

11. Air-to refrigerant heat exchanger : transfers heat from the compressed air to the cold refrigerant, forcing water vapour in the compressed air to condense. The more effective the heat transfer, the cooler the air becomes and the more water vapour condenses.

 

12. Air/ air heat exchanger

 

13. Water separator : collects and drains off condensate from the cooled air flow. The more efficient the separation, the better the pressure dewpoint, as droplets which are not collected revapourise and degrade the pressure dewpoint. The collected droplets are reliably evacuated from the separator through an electronic drain.

 

14. Automatic drain

 

15. Air outlet : re-heats the outgoing air to prevent condensation on the factory’s pipework.

 

 

 

 

Specifications

ManufacturerAtlas copco
ModelOutlet pressure dew point
ConditionNew
Warranty1 Year
Applicable industriesManufacturing Plant Food & Beverage Factory
Showroom locationUnited Kingdom Indonesia Russia
Video outgoing-inspectionProvided
Machinery test reportProvided
Marketing typeOrdinary Product
Place of originJiangsu China
TypeAir Dryer
BrandAtlas Copco IR BLT DBD
Moq1set
Delivery5 Working Day
ColorBlue
PackageOriginal Packing
Stock5000set
CertificateISO9001
After warranty serviceVideo technical support Online Spare parts
Local service locationRussia Spain
Model numberFX 1-16